Expansion Modules

DSE2130

DSENet® Input Expansion Module

The DSE2130 DSENet® Input Expansion Module has been developed for use with DSE modules. The DSE2130 extends the host modules input capabilities for increased application flexibility. This is achieved by providing an additional 8 inputs, consisting of 4 analogue inputs (can be configured as digital) and 4 digital inputs. 

For enhanced communication with the host module, the DSE2130 features a DSENet® port for connection to DSE modules. A red status LED is provided to easily identify when the DSE2130 is connected to a power source and communicating with the host controller. 

OVERALL SIZE
134 mm x 76 mm x 49 mm (5.3” x 3.0” x 1.9”) 
WEIGHT
0.18kg
PRODUCT VARIANTS
2130-00 - 2130 Input Expansion Module

Request a Quote

e -
Please select a product
Please enter a quantity
e +

add another product

Please enter your title
Please enter your first name
Please enter your surname
Please enter your company name
Please select your country
Please enter a delivery County/State
Please enter your email
Please enter your mobile number
Webform URL: Website Option: Webform: Named Distributor: Distributor's Email: Named Reseller: Reseller's Email:


l

Product Highlights

Key Features

Key Features

DIN rail & chassis mount.
Power on/link lost LED.
1.2km (0.75 Mile) working range.
Connect maximum of 4 x DSE2130’s to a single host controller.
Rotary ID switch to select address of DSE2130 to talk with host module when multiple DSE2130 modules are in use.
Max of 32 digital inputs – 16 can be configured for use as analogue.

Specification

DC SUPPLY

CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.
 

MAXIMUM OPERATING CURRENT
200 mA at 12 V, 100 mA at 24 V

MAXIMUM STANDBY CURRENT
120 mA at 12 V, 60 mA at 24 V
 

Environmental Testing Standards

ELECTRO-MAGNETIC  COMPATIBILITY
BS EN 61000-6-2
EMC Generic Immunity Standard for the Industrial Environment.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.

ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.

TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.

VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three major axes.
5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn.

HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55° C @ 95% RH 48 Hours.
BS EN 60068-2-78
Cab Damp Heat Static 40° C @ 93% RH 48 Hours.

SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes 15 gn in 11 ms.

Connection Diagram

DSE2130 connection diagram

Product Variants

 2130-00 - 2130 INPUT EXPANSION MODULE